Gas connection – Bertazzoni Master Series 36 Inch Gas Rangetop Installation, Use & Care Manual User Manual
Page 12
12
/ Gas connection
Warning!
DO NOT USE AN OPEN FLAME WHEN
CHECKING FOR LEAKS!
Leak testing of the appliance shall be conducted
according to the manufacturer’s instructions. Be-
fore placing the oven into operation, always check
for leaks with soapy water solution or other accep-
table method.
Check for gas leakage with soapy water solution or
other acceptable methods in all gas connections
installed between inlet gas pipe of the appliance,
gas regulator, till to the manual shut-o
ff
valve.
All gas connections must comply with national and
local codes. The gas supply line (service) must
be the same size or greater than the inlet line of
the appliance. This rangetop uses a 1/2” NPT inlet
(see drawing below for details of gas connection).
On all pipe joints use appropriate sealant resistant
to gas to joint the adapter to rangetop manifold
use only the blue gasket supplied.
If necessary, the appliance must be converted by
the dealer, by a factory-trained professional or by
a quali
fi
ed licensed plumber or gas service com-
pany.
Gas conversion is important for safe and e
ff
ecti-
ve use of the appliance. It is the responsibility of
the dealer and the owner of the range to perform
the appropriate gas conversion following the di-
rections of the manufacturer.
THE GAS CONVERSION PROCEDURE IS
DESCRIBED IN THIS MANUAL AND IN THE
PACKAGE CONTAINING THE CONVERSION
NOZZLES SHIPPED WITH EVERY RANGETOP.
Please provide the service person with this ma-
nual before work is started on the rangetop.
MANUAL SHUT-OFF VALVE
THIS VALVE IS NOT SHIPPED WITH THE AP-
PLIANC AND MUST BE SUPPLIED BY THE IN-
STALLER.
The manual shut-o
ff
valve must be installed in the
gas service line between the gas hook-up on the
wall and the appliance inlet, in a position where it
can be reached quickly in the event of an emer-
gency.
In Massachusetts:
A ‘T’ handle type manual
gas valve must be installed in the gas supply line
to this appliance.
FLEXIBLE CONNECTIONS
In case of installation with
fl
exible couplings and/
or quick-disconnect
fi
ttings, the installer must use
a heavy-duty, AGA design-certi
fi
ed commercial
fl
exible connector of at least 1/2” (1.3 cm) ID NPT
(with suitable strain reliefs) in compliance with
ANSI Z21.41 and Z21.69 standards.
In Massachusetts:
The unit must be installed
with a 36” (3-foot) long
fl
exible gas connector.
In Canada:
use CAN 1-6.10-88 metal connec-
tors for gas appliances and CAN 1-6.9 M79 quick
disconnect device for use with gas fuel.
PRESSURE TEST-POINT STOPPER
VALVE
To avoid gas leaks, the pressure test-point stop-
per valve and gasket supplied with the rangetop
must be installed on the gas
fi
tting at the back of
the rangetop according to the diagram below.
GAS CONNECTION
GAS PIPE
GASKET
PRESSURE TEST-POINT
STOPPER
GAS CONNECTION ADAPTOR
1/2’’NPT WITH PRESSURE TEST
POINT 1/8’’ NPT (TO BE FIXED
TOWARD EXTERNAL SIDE OF
THE APPLIANCE)
ELBOW