Data rating label before installation – Bertazzoni Master Series 36 Inch Gas Rangetop Installation, Use & Care Manual User Manual
Page 6
6
/ Data rating label / Before installation
The data rating label shows the model and serial
number of the rangetop. It is located under the
rangetop and in the last page of this manual.
• DO NOT remove permanently a
ffi
xed labels,
warnings, or plates from product. This may
void the warranty.
• This appliance shall only be installed by an
authorized professi
onal.
• This appliance shall be installed in accordance
with the manufacturer’s installation
instructions.
• This appliance must be installed in accordance
with the norms & standards of the country
where it will be installed.
• The installation of this appliance must conform
to local codes and ordinances. In the absence
of local codes, Installations must conforms to
American National Standards, National Fuel
Gas Code ANSI Z223.1 – latest edition/NFPA
54 or B149.1.
• The appliance, when installed, must be
electrically grounded in accordance with local
codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70.
If local codes permit, a
fl
exible metal appliance
connection conduit with the new AGA or CGA cer-
ti
fi
ed design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended for connecting this appliance to the
gas supply line. Do not bend or damage the
fl
exi-
ble connector when moving the appliance.
This appliance must be used with the pressure
regulator provided.
The regulator shall be properly installed in order to
be accessible when the appliance is installed in its
fi
nal location. The pressure regulator must be set
for the type of gas to be used. The pressure regu-
lator has ½” female pipe thread. The appropriate
fi
tting must be determined based on the size of
your gas supply line, the
fl
exible metal connector
and the shuto
ff
valve.
The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual
shuto
ff
valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 PSI (13,8” w.c. or 3,5 kPa).
All opening and holes in the wall and
fl
oor, back
and under the appliance shall be sealed before
installation of the appliance.
A manual valve shall be installed in an accessible
location in the gas line external to the appliance
for the purpose of turning on or shutting o
ff
gas to
the appliance.
Type of gas
This range can be used with Natural or LP/Pro-
pane gas. The range is shipped from the factory
for use with the gas indicated on the rating label
positioned on the lower face of the control panel
and in the last page of this manual. A step by step
conversion procedure is also included in this ma-
nual and in each conversion kit.
Gas pressure
The maximum inlet gas supply pressure inco-
ming to the gas appliance pressure regulator is
1/2 PSI (13,8’’ iwc or 3,5 kPa). The minimum gas
supply pressure for checking the regulator setting
shall be at least 1“ iwc (249 Pa) above the inlet
speci
fi
ed manifold pressure to the appliance; this
operating pressure is 4” iwc (1.00 kPa) for Natural
Gas and 10” iwc (2.50 kPa) for LP Gas.
Room ventilation
An exhaust fan may be used with the appliance;
in each case it shall be installed in conformity
with the appropriate national and local standards.
Exhaust hood operation may a
ff
ect other vented
appliances; in each case it shall be installed in
conformity with the appropriate national and local
standards.
Warning
This appliance should not be installed with a
ventilation system that directs air in a downward
direction toward the range. This type of ventila-
tion system may cause ignition and combustion
problems with the appliance resulting in personal
injury, property damage, or unintended operation.
Ventilating systems that direct the air upwards do
not have any restriction.
Do not use aerosol sprays in the vicinity of
this appliance while it is in operation.
DATA RATING LABEL
BEFORE INSTALLATION