GAS CONVERSION
Adjusting the cooktop burner minimums
When switching from one type of gas to another, the minimum flow rate must also be correct:
●
The flame should not go out even when passing suddenly from maximum to minimum flame.
To regulate the flame follow these instructions:
Semi-rapid burner (
A
)
●
Light the burner.
●
Set the gas valve to
position (minimum rate).
●
Remove the dial.
●
With a thin screwdriver, turn the regulation screw inside the tap rod until adjustment is correct.
Inside crown of DUAL burner (
B
)
●
Light the DUAL burner.
●
Set the gas valve to
position (minimum rate of inner crown).
●
Remove the dial.
●
With a thin screwdriver, turn the regulation screw until adjustment is correct.
The screw is accessible via a hole in the microswitch.
Outside crown of DUAL burner (
C
)
●
Light the DUAL burner.
●
Set the gas valve to
position (minimum rate of outer crown and maximum rate of inner crown).
●
Remove the dial.
●
With a thin screwdriver, turn the regulation screw inside the tap rod until adjustment is correct.
For LP/PROPANE gas, tighten the adjustment screws completely.
A
Regulation screw (Semi-Rapid burner)
B
Regulation screw (Inner crown of dual burner)
C
Regulation screw (Outer crown of dual burner)
B
A
C
Regulation
screws
Regulation
screws
Regulation
screws