terminal resistance settings. All of the settings should be confirmed before the dome is

installed. The control-related setting that is address, communication protocol and

transmission speed have to be set consistently with the control device such as a keyboard

or a DVR.

Notice: Please make sure the power is off before setting, and restart the

EPTZ3100/EPTZ3100I to enable a new value after changing.

2.3.1. Address Setting

The address code of the EPTZ3100/EPTZ3100I should be set to correspond properly

with a control device to control multiple dome cameras. The address codes are made

up by the dip switch on the camera main body. The 8 bits dip switch indicates the

binary coded of the address, and there are 256 addresses can be selected (0 ~ 255). It

also means that there are up to 256 dome cameras that can cascade on the RS-485

bus. The dip switch setting and the indicated address are represented in the following

diagram.

Note: The factory default address is 1.