beautypg.com

Installation steps – Hestan 30 Inch Drawer Microwave Installation Manual User Manual

Page 12

background image

INSTALLATION STEPS

ANTI-TIP BLOCK

To reduce the risk of tipping of the drawer, the Anti-Tip block must be properly installed. It must

be located 14 13/16 in. [37.6 cm] above the floor on which the Drawer Microwave will sit. The

6-in. [15.2 cm] Anti-Tip block must be provided by the installer. See the figures for necessary

dimensions. The Anti-Tip block prevents serious injury that might result from spilled hot liquids.
If the Drawer Microwave is ever moved to a different location, the Anti-Tip block must also be

moved and installed. When installed to the wall, make sure that the screws completely penetrate

the dry wall and are secured in wood or metal so that the block is totally stable. When fastening,

be sure that the screws do not penetrate electrical wiring or plumbing.

ELECTRICAL CONNECTION

The appliance requires a 120 volt, 60 Hz, AC only, 15 amp or more

protected electrical supply. It is recommended that a separate circuit

serving only this appliance be provided.
The appliance is equipped with a 3-prong grounding plug. It must

be plugged into a wall receptacle that is properly installed and

grounded. Should you only have a 2-prong outlet, have a qualified

electrician install a correct wall receptacle. Do not cut or remove

the grounding prong from this plug.
Note: If you have any questions about the grounding or electrical

instructions, consult a qualified electrician or service person.

GROUNDING INSTRUCTIONS

This appliance must be grounded. The Drawer Microwave is equipped with a cord having a

grounding wire with a grounding plug. It must be plugged into a wall receptacle that is properly

installed and grounded in accordance with the National Electrical Code and local codes and

ordinances. In the event of an electrical short circuit, grounding reduces risk of electric shock by

providing an escape wire for the electric current.

Improper use of the grounding plug can result in a risk of electric shock.

DO NOT USE AN

EXTENSION CORD. IF THE POWER SUPPLY CORD IS TOO SHORT, HAVE A QUALIFIED

ELECTRICIAN OR SERVICEMAN INSTALL AN OUTLET NEAR THE APPLIANCE.

3-Prong plug

Grounding prong

3-Prong receptacle

Grounded receptacle box

Correct Installation

FLUSH MOUNTING

For flush mount installation, mount and secure the deflector vent. See instructions on previous

pages.

PLACING DRAWER

1. Place the drawer adjacent to the wall or cabinet opening. Plug the power supply cord into the

electrical outlet.

2. Carefully guide the drawer into the prepared opening. Avoid pinching the cord between the

oven and the wall.

3. Slide the drawer all the way until the mounting flange is flush with the face of the cabinet.

See Figure 10.

4. Open the drawer. Using the 4 holes on the drawer as a template, pre-drill the cabinet using a

1/16" [1.45 mm] bit.

5. Secure the drawer with the 4 screws supplied.

©2019 Hestan Commercial Corporation

10

EN