16

When engaged, this function will allow the lamp to be switched “off” via a DMX

controller. Select “ON” to enable this function or “OFF” to disable it.

Lamp On at Temp.

The fixture is designed to shut the lamp off when an excessive temperature is

sensed inside the head by the on-board CPU. The lamp is shut down to prevent

damage to the lamp and avoids possible internal damage to the head. This function

sets the minimum temperature for lamp restrike after the lamp has been

automatically shut off.

Lamp Off at Temp.

The fixture is designed to shut the lamp off when an excessive temperature is

sensed inside the head by the on-board CPU. The lamp is shut down to prevent

damage to the lamp and avoids possible internal damage to the head. This function

sets the maximum internal operating temperature of the head before the lamp will

automatically be shut down. This function can be set to activate at an internal

temperature between 80° C and 139° C. Inside temperatures below 90° C are not

critical. Temperatures above 90° C should lead to the lamp being switched off.

Please note that the outside temperature should not exceed 45° C.

Personality:

Status setting

Address via DMX - This function allows the DMX address to remotely be

adjusted from a DMX console. This setting requires special settings for both the

controller and the fixture. RDMX is on by default. For operational instructions

please see Section 10/Page 35 of this manual “Remote DMX addressing.”