Information:

Time information

These functions will detail different time functions associated with the fixture.

Current Time

This function displays the running time of the fixture from the last power on. The

display shows “XXXX”, where “XXXX” represents the number of hours the fixture

has been running. This counter is automatically reset after every power-on.

Total Run Time

This function tracks the total running time of the fixture from the very first start-

up. Where “XXXX ”represents the total number of running hours. This time is

none destructive and will remain in the fixtures memory indefinitely.

Last Run Hours

This function tracks a cycle run time. Use this function to keep track of rental

period, or to note the time from the last service. This setting can be reset at any

time.

“L-Timer Password.”

Lamp Hours. This function tracks the total number of lamp running hours. Where

“XXXX” represents the number of hours the lamp has been running. This

counter should be reset after every lamp change.

Lamp Off Time

This function displays the running time of the lamp from the last power on. The

display shows “XXXX”, where “XXXX” represents the number of hours the lamp

has been running since it was last struck. This counter is automatically reset

after every power-on.

Timer Password

Use this function to enter the “Clear Last Run” password. Password is “038”

Clear Last Run

This function will allow the “Last Run Hours” function be cleared and reset.

L-Timer Password

Use this function to enter the “Clear Lamp Time” password. Password is “038”