15

Clear Lamp Time

This function resets the lamp “ON” time to zero. Please reset the lamp “ON” time

at every lamp replacement. This procedure tracks the lamp running time so the

lamp can be replaced at the end of it’s recommended duty cycle.

• Select “Clear lamp time” in the system menu.

• The LCD will display “ON” or “OFF.” Were “ON” will reset the lamp time.

• Press enter to confirm.

• Press the Mode/Esc-button to return to the main menu.

Temperature Info.

This function will detail the internal head temperature in either Celsius or

Fahrenheit.

Software version

This function will display the current operating software version of the fixture.

• The LCD will read “V-X.X”, “X.X” represents the version number, e.g. “V-1.0”,

“V-2.6”.

• Use the UP and DOWN buttons to toggle through the software version of

different IC’s.

Lamp Control:

Lamp On or Off

This function allows manual control of the lamp power via the on-board system

menu.

• Select “ON” if you wish to strike the lamp or “OFF” to switch it off.

• Press “ENTER” to confirm.

• Press the Mode/Esc-button to return to the main menu.

Automatic La-On

When in the “ON” position, this function will automatically turn the lamp on when

power is applied to the fixture

Lamp On Via DMX

When engaged, this function will allow the lamp to be switched “on” via a DMX

controller. Select “ON” to enable this function or “OFF” to disable it.

Lamp Off Via DMX

- - XM542-V1.0-NR