beautypg.com

Maintenance and service, Routine maintenance, Cleaning the painted surfaces – Enviro C-11366 User Manual

Page 9: Check pilot and burner flames, Glass door removal

background image

9

Maintenance And Service

R

OUTINE

M

AINTENANCE

:

At least once a year, run through the following procedures to ensure the system is clean and working

properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not

blocked by anything. The pilot flame should be blue with little or no yellow on the tips.
Warning: Clearances must be sufficient to allow access for maintenance and service

Warning: Failure to position the parts in accordance with this manual, or failure to use only parts

specifically approved with this appliance may result in property damage or personal injury.
The venting system must be periodically examined; it is recommended the examination is done by a
qualified agency.

C

LEANING

T

HE

P

AINTED

S

URFACES

:

Painted faces should be wiped with a damp cloth periodically.

C

HECK

P

ILOT

AND

B

URNER

F

LAMES

:

Figure 7: Door Removal / Installation.

IMPORTANT: If the door is not engaged

properly on the hooks, damage to the

fireplace and/or floor, personal injury, or

even death may occur.
1. Turn the unit off and wait until it has

cooled down.

2. Remove the cast iron louvers from above

the door by lifting the louvers up and

out.

3. Pull the two (2) door hooks, on top of the

door, forward and up (see Figure 7).

4. Lift the glass door assembly straight up

and out.

Ensure the door is properly fastened before

attempting to light the appliance. To re-

installing the glass door, slide the three (3)

door hook slots, on the bottom of the door,

over the three (3) door hooks on the unit.

Pull the two (2) door hooks, on top of the

door, forward and slide them into the two

(2) door hook slots.

Periodically do a visual check of the pilot flames. One flame

should encompass the ignitor and thermocouple and the

other should burn over the burner ports (see Figure 6). Also

check that the burner is operating correctly, refer to Figure

Figure 43 or Front Cover.

G

LASS

D

OOR

R

EMOVAL

:

Figure 6: Pilot Flame.

This manual is related to the following products: