beautypg.com

Gas line connection and testing, Initial installation, Never use an open flame for leak testing – Enviro C-11366 User Manual

Page 20: Qualified installers only g

background image

Initial Installation

QUALIFIED INSTALLERS ONLY

G

AS

L

INE

C

ONNECTION

AND

T

ESTING

:

WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to

this appliance.

O

L I

T

P

TP

TH

TP

TH

IN

OU

T

H

I

LO

N

OF

O

F

LI

P

T O

Manifold

Pressure Tap

Inlet

Pressure Tap

Hi/Low

Knob

Pilot Adjustment

Screw

Gas Control

Knob

Figure 33: Fully Labeled Gas Valve.

GAS LINE CONNECTION
• This stove is equipped with a certified flexible pipe

located on the right side of the unit terminating in a 3⁄8”

male NPT fitting. Consult your local authorities codes or

the CAN/CGA B 149 (1 or 2) installation code in Canada,

or in the USA gas installations follow either local codes

or the current edition of the National Fuel Gas Code ANSI

Z223.1.
• The efficiency rating of this appliance is a product

of the thermal efficiency rating determined under

continuous operating conditions and was determined

independently of any installed system.
The appliance and its shutoff valves must be disconnected from the gas supply piping system during any

pressure testing where the pressure exceeds 1⁄2 PSIG (3.45 KPa) or damage will occur to the valve.
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff

valve during any pressure testing of the gas supply piping system at test pressures equal to or less than

1⁄2 psig (3.45 KPa).

Always check for gas leaks with a soap and water solution after completing the

required pressure test.

TO TEST VALVE PRESSURES

The pressure taps are located on the left side of the valve

• Turn set screw 1 turn counter clockwise to loosen,

• Place

5

/

16

” (8 mm) I.D. hose over pressure tap system.

• Check pressures using a manometer.

• When finished, release pressure, remove hose & tighten set screw.

Table 8: Pressure and BTU Information.

Natural Gas

Propane

Main Burner

PO512-42 DMS

PO512-54

Manifold Pressure

3.8” W.C. / 0.95KPa

11.0” W.C. / 2.7KPa

Min. Manifold Pressure

1.1” W.C. / 0.27KPa

2.9” W.C. / 0.72KPa

Max Supply Pressure

7.0” W.C. / 1.74KPa

13.0” W.C. / 3.28KPa

Min. Supply Pressure

5” W.C. / 1.24KPa

12.0” W.C. / 2.98KPa

Max BTU/hr Input 26,000 BTU/hr (7.62 KW)

26,000 BTU/hr (7.62 KW)

Min. BTU/hr Input

15,000 BTU/hr (4.4 KW)

14,000 BTU/hr (4.1 KW)

Venturi Setting

1⁄4” (6mm) minimum

Completely Open

NEVER USE AN OPEN FLAME FOR LEAK TESTING.

20

This manual is related to the following products: