beautypg.com

Initial installation, Preparation for installation, Clearances to combustibles – Enviro C-11366 User Manual

Page 14

background image

14

Initial Installation

QUALIFIED INSTALLERS ONLY

WARNING: Operation of this heater when not connected to a properly installed and maintained venting

system can result in carbon monoxide (CO) poisoning and possible death.

P

REPARATION

F

OR

I

NSTALLATION

:

• If you are converting to a Cara DR unit, follow the instructions in this Manual, especially

referencing the Conversion and Venting sections.

• Remove the packaging from the appliance, and check to make sure there is no damage. If damage is

found, please report it to both the carrier and your dealer as soon as possible.

• Before beginning, carefully check the glass door and the log set
• Locate a position where the flue system of the stove can be properly installed without damaging the

integrity of the building; e.g. cutting a wall or ceiling joist.

• Check stove and flue system clearance requirements.
• Locate the stove where it can be accessed by a gas supply line.
• Locate the stove in a large and open room that is centrally located in the house. This will optimize heat

circulation and comfort.

• As the stove can be equipped with a convection fan, ensure that an electrical outlet is within 6 ft (1.8

m) of the stove.

• The flow of combustion and ventilation air must not be obstructed.

C

LEARANCES

TO

C

OMBUSTIBLES

:

CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.

Table 3: Clearance to Walls in an Open Area, refer to Figure 23.

Letter

Description

Clearance

A

Sidewall to unit

11 inches (279 mm)

B

Backwall to unit

2.5 inches (64 mm)

C

Corner to unit

2.5 inches (64 mm)

D

Ceiling to floor

90 inches (2286 mm)

E

Floor (on hardwood and linoleum)

0 inches (0 mm)

Figure 23: Clearance to Walls in an Open Area, refer

to Table 3.

Table 4: Clearance to Walls in an Alcove

Description

Clearance

Minimum Width

431⁄2 inches (1105 mm)

Minimum Height

48 inches (1219 mm)

Maximum Depth

24 inches (610 mm)

B

A

Back Wall

S

id

e

W

al

l

C

Adja

cen

t W

all

This manual is related to the following products: