beautypg.com

List of functions – Epson EB-825 User Manual

Page 38

background image

Sub Menu

Function

Control Panel Lock

You can use this to restrict operation of the projector's Control panel. s

p.31

Pointer Shape

You can select the shape of the pointer. s

p.25

Pointer 1:

Pointer 2:

Pointer 3:

Brightness Control

You can set the Lamp brightness to one of two settings.
Select Low if the images being projected are too bright such as when projecting images in a dark room or onto a small screen. When Low is
selected, the amount of electricity consumed and the lamp's operating life are changed as follows, and fan rotation noise during projection is
reduced. Electrical consumption: about 25% decrease, lamp life: about 1.2 times longer

Volume

You can adjust the Volume. Setting details are saved for each image signal.

Mic Input Volume

Adjust if the Mic Input level is too low to hear from the projector's speaker, or if the level is too high making the audio crack. When the Mic Input
Volume is turned down to 0, no audio is output from the speaker.

Remote Receiver

You can limit the reception of the operation signal from the Remote Control.
When you want to prohibit operation by Remote Control, or if the Remote Receiver has a fluorescent light too close to it, you can make settings to
deactivate the remote receiver you do not want to use or that is experiencing interference.

User Button

You can select the item assigned from the Configuration Menu with the Remote Control's [User] button. By pressing the [User] button the
assigned menu item selection/adjustment screen is displayed, allowing you to make one-touch settings/adjustments. You can assign one of the
following five items to the [User] button.
Brightness Control, Info, Progressive, Test Pattern, Resolution

Test Pattern

When the projector is setup, a Test Pattern is displayed so that you can adjust the projection without connecting other equipment. While the Test
Pattern is displayed, zoom, focus adjustments, and Keystone correction can be performed.
To cancel the Test Pattern, press the [Return] button on the Remote Control or the Control panel.

Reset

You can reset all adjustment values on the Settings menu to their default settings, except for User Button.

To return all menu items to their default settings, see s

p.52

List of Functions

38