3.4 ALARM SETUP MENU

In the ALARM SETUP MENU, we define :

(1) ALARM:

ENABLE: Enable alarm detection.

DISABLE: Disable alarm detection.

(2) ALARM TYPE:

N. O. : Normal Open alarm.

N.C. TRANS. : When the alarm is triggered, buzzer starts to function no matter how long is the

alarm duration set until you set it back to N.C.

N.O. TRANS. : When the alarm is triggered, buzzer starts to function no matter how long is the

alarm duration set until you set it back to N.O.

N. C. : Normal Close alarm.

(3) ACTIVE CAMERA:

Active camera setting, from camera 01~16. You can set the camera which corresponds to the place

where the alarm is located.

Note: The recording camera number in an event depends on the alarm number, and the focus camera

images will not be recorded. For example: You assign camera 3 as the focus camera to alarm 1.

When the alarm 1 is triggered, camera 3 will be displayed and camera 1 will be recorded.