beautypg.com

Laser exposure warning, Laser emission data, Laser compliance statement – CHAUVET DJ Helicopter Q6 - Rotating Multi-Effects Light with Laser (RGBW) User Manual

Page 12: Laser safety label reproduction, Before you begin, Laser exposure warning laser emission data, Page 6 of 94, Helicopter q6 user manual rev. 2

background image

Page 6 of 94

Before You Begin

Helicopter Q6 User Manual Rev. 2

Laser Exposure Warning

Laser Emission Data

As measured under IEC measurement conditions for classification.

Laser Compliance Statement

This laser product complies with EN/IEC 60825-1 Ed 2, 2007-03, and U.S. FDA/CDRH FLPPS via the

terms of Laser Notice No. 50 dated June 24, 2007. This laser device is classified 3R. (Class 3R is the

international equivalent of U.S. Class IIIa.) No maintenance is required to keep this product in compliance

with laser performance standards.

Laser Safety Label Reproduction

LASER LIGHT AVOID DIRECT EYE EXPOSURE

Further guidelines and safety programs for safe use of lasers can be found in the ANSI

Z136.1 Standard “For Safe Use of Lasers”, available from the Laser Institute of America:

www.lia.org

. Many local governments, corporations, agencies, military, and others, require

all lasers to be used under the guidelines of ANSI Z136.1. Laser Display guidance can be

obtained via the International Laser Display Association:

www.ilda.com

.

Laser Classification

Class 3R

Green Laser Medium

DPSS Nd:YVO4, 532 nm/30 mW

Red Laser Medium

LD GaAIAs, 650 nm/100 mW

Beam Diameter

<5 mm at aperture

Pulse Data

All pulses < 4 Hz (>0.25 sec)

Divergence (each beam)

<2 mrad

Divergence (total light)

<160 degrees

Laser Power of Each Beam from Aperture*

<5 mW

Bottom

Top

MODEL:

HELICOPTERQ6

ITEM CODE:

10051300

FUSE:

F 1.6 A, 250 V

POWER LINKING:

8 A

(12 UNITS @ 120 V)

(23

UNITS

@

230

V)

ORIGIN:

MADE

IN

CHINA

USA / CANADA
POWER: 100-125 VAC, 60 Hz
0.7 A, 41 W

WORLDWIDE
POWER: 100-240 VAC, 50/60 Hz
0.4-0.7 A, 44 W

THIS APPLIANCE MUST BE GROUNDED
CETTE UNITÉ DOIT ÊTRE RELIÉE À LA TERRE
USE ONLY FUSE OF SAME TYPE & RATING
N’UTILISER QUE DES FUSIBLES DU TYPE ET
DE L’AMPÉRAGE INDIQUÉ
NOT FOR HOUSEHOLD USE
IMPROPRE A L’USAGE DOMESTIQUE
DRY LOCATIONS
EMPLACEMENTS SECS
DISCONNECT POWER BEFORE SERVICING
DÉBRANCHER AVANT TOUT ENTRETIEN
FOR INDOOR USE ONLY
USAGE INTÉRIEUR UNIQUEMENT

WORLDWIDE HEADQUARTERS,

SUNRISE, FLORIDA USA

30/532/100mW/650nm

CW, <5mW

WARNING

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

IEC/EN60825-1:2014

!"#$%&'(

RoHS