beautypg.com

He section, Jp5 & jp6 – can bus termination, Section – Eurotech Appliances ZEUS PXA270 User Manual

Page 95: Jp7 - jtag enable, Jp5&jp6

background image

ZEUS Technical Manual

Connectors, LEDs and jumpers

© 2007 Eurotech Ltd Issue D

95

JP5 & JP6 – CAN bus termination

Connector:

2-way, 2.54mm (0.1") through-hole header

JP5

JP6

Pin Signal name

Pin Signal name

1

CANH

1

Centre tap

2 Centre

Tap

2 CANL

JP5 & JP6

Description

62Ω Termination connected

62Ω Termination disconnected

(default)

Only insert jumpers JP5 and JP6 if the ZEUS is at the end of the network.

JP7 - JTAG Enable

Connector:

2-way, 2.54mm (0.1") through-hole header

Pin Signal

name

1 VCC

(+5V)

2 VCC_JTAG



This jumper is used to enable debug of PXA270 using JTAG interface.

JP7 Description

JTAG Enable

Normal Operation (Default)

Only insert jumper JP7 for JTAG access to PXA270.

JP6

JP5

1 2

2 1

1

2