beautypg.com

Serial com ports, Serial pc/104, 2 rs232 – Eurotech Appliances ZEUS PXA270 User Manual

Page 53: For f, Uart 1, Uart 2, Uart 3, Uart 4

background image

ZEUS Technical Manual

Detailed hardware description

© 2007 Eurotech Ltd Issue D

53

Serial COM ports

There are seven serial communications ports available on the ZEUS. Three are

provided by the PXA270 and are used for the optional wireless modem, GPS and

IEEE802.15.4 / ZigBee ports.
There are four additional high-speed, 16550 compatible serial UARTs implemented by

an EXAR ST16C554Q Quad UART device. Two of these channels (COM1, COM2) can

be used as standard RS232 serial interfaces, COM3 can be configured as RS232 or

RS485/422, and COM4 can be configured as RS422 or RS485. The table below

provides a summary of the four additional serial ports.

Port Address

IRQ

FIFO depth

RX / TX

Signals

COM1 0x10000000

0x1000000F

GPIO9

16/16 RS232: Rx, Tx, CTS, RTS, RI,

DSR, DCD, DTR

COM2 0x10800000

0x1080000F

GPIO10

16/16 RS232: Rx, Tx, CTS, RTS, RI,

DSR, DCD, DTR

COM3 0x11000000

0x1100000F

GPIO12

16/16 RS232: Rx, Tx, CTS, RTS, RI,

DSR, DCD, DTR
or
RS422/485: Rx, Tx

COM4 0x11800010

0x1180001F

GPIO11 16/16

RS422/RS485:

Rx,

Tx

COM1/2 – RS232 interface

Supported on Channel A and B of the external Quad UART, the ports are buffered to

RS232 levels with ±15kV ESD protection, and support full handshaking and modem

control signals. The maximum baud rate is 921.6 Kbaud. COM1 and COM2 ports can

be accessed using DB9 connectors J11 and J15, respectively. For pin assignment and

connector details, see

J11 – Serial port – COM1

on page

83

and

J15 – Serial port –

COM2

on page

86

.

A factory fit option configures COM1 as TTL Level signals to interface to certain

specialized modems. Please contact

Eurotech Technical Support

(see page

97

) for

details.