beautypg.com

Watchdog timer, 0000 16-bit, Reg3 (wd register) – Eurotech Appliances ZEUS PXA270 User Manual

Page 32

background image

ZEUS Technical Manual

Detailed hardware description

© 2007 Eurotech Ltd Issue D

32

Watchdog timer

The ZEUS uses an external watchdog timer (MAX6369) which can be used to protect

against erroneous software. This is a programmable watchdog timer that can be

adjusted for timeout periods of 1ms, 10ms, 30ms, 100ms, 1s, 10s and 60s. The board

is reset when timeout occurs. The MAX6369 watchdog timer can be programmed

using the WD setup register provided within the CPLD. The register is memory

mapped (accessible through CS5#). The WDT is disabled upon reset, and remains so

until enabled by the software.

The following table shows the WD setup register bit definitions:

Watchdog Register [REG3]

Bits Description
7:4 Not

used.

3

WDI: Watchdog Input. If WDI remains either high or low for the

duration of the watchdog timeout period (t

WD

), WDT triggers a reset

pulse. The internal watchdog timer clears whenever a reset pulse

is asserted or whenever WDI sees a rising or falling edge.

2:0

WDSET[2:0] – watchdog enable / timeout period setup bits.

Hex Offset Address:

0x13800000

Reset Hex Value:

0x03

Access:

Read/write

For further details, see the Intel PXA27x Processor Family Developer’s Manual on the