beautypg.com

Eurotech Appliances ZEUS PXA270 User Manual

Page 48

background image

ZEUS Technical Manual

Detailed hardware description

© 2007 Eurotech Ltd Issue D

48

The LVDS transmitter can be programmed for rising edge strobe or falling edge strobe

operation through a signal LVDS_FES# (Expander 2 – GPIO1, I2C address 0x22).

Details are shown in the following table:

LVDS_FES#
(EXP2_GPIO1)

Selected LVDS function

0

Falling edge strobe

1

Rising edge strobe (default)

Connector

J24

should be used to supply the power and brightness control for the

backlight inverter when the LVDS interface is used. See the section

J24 – Backlight

power