The LVDS transmitter can be programmed for rising edge strobe or falling edge strobe
operation through a signal LVDS_FES# (Expander 2 – GPIO1, I2C address 0x22).
Details are shown in the following table:
LVDS_FES#
(EXP2_GPIO1)
Selected LVDS function
0
Falling edge strobe
1
Rising edge strobe (default)
Connector
J24
should be used to supply the power and brightness control for the
backlight inverter when the LVDS interface is used. See the section