Page 32: Command, No. command type command value range

background image

32

Control Codes

Viewing control state (Get control command)

Header

Command

ID

Data length

Checksum

0xAA

Command
type

0

Controlling (Set control command)

Header

Command

ID

Data length

Data

Checksum

0xAA

Command
type

1

Value

Command

No.

Command type

Command

Value range

1

Power control

0x11

0~1

2

Volume control

0x12

0~100

3

Input source control

0x14

-

4

Screen size control

0x19

0~255

5

Video wall mode control

0x5C

0~1

6

Safety Lock

0x5D

0~1

7

Video Wall On

0x84

0~1

8

Video Wall User Control

0x89

-

All communications take place in hexadecimals. The checksum is calculated by adding

up all values except the header. If a checksum adds up to be more than 2 digits as shown

below (11+FF+01+01=112), the first digit is removed.

E.g. Power On & ID=0

Header

Command

ID

Data length

Data 1

Checksum

0xAA

0x11

1

"Power"

Header

Command

ID

Data length

Data 1

12

0xAA

0x11

1

1

To control all devices connected by a serial cable simultaneously irrespective of IDs, set

the ID as "0xFE" and transmit commands. Commands will be executed by each device but

ACK will not respond.