Read kernel parameters, Run config mode, Update an-x flash – ProSoft Technology AN-X-AMX User Manual
Page 37

AN-X-AMXRIO Page
33
Possible status values are:
Value
Meaning
1
Boot mode
2
Configuration mode
4
Production mode
Read Kernel Parameters
The Utilities/Read Kernel Parameters command displays various communications
parameters for the currently selected AN-X
This command resets the AN-X. You will be warned and given the opportunity to cancel
the command.
The Utilities/Read Kernel Parameters command leaves the AN-X running the boot code.
Use the Utilities/Restart AN-X command to restart the AN-X in production mode.
Run Config Mode
The Utilities/Run Config Mode command is used to restart the currently selected AN-X
in configuration mode (normally used internally for updating firmware).
This command is not used in normal operation but may be required for technical support.
When the AN-X is in configuration mode, the SYS LED flashes red twice, followed by a
pause.
To exit configuration mode, use the Utilities/Restart AN-X command to restart AN-X in
production mode.
Update AN-X Flash
The Utilities/Update AN-X Flash command updates the low-level firmware
(configuration kernel and production kernel).
Files have extension qtf. Current AN-X kernel files are provided on the distribution CD.