Introduction, General specifications, Resources – ProSoft Technology 5202-DFNT-GRCM4 User Manual
Page 3: 1 introduction, 1 general specifications, 2 resources
1 Introduction
The GRCM driver permits the ProLinx Communication Gateways, Inc. module to interface
GARECO Check Weigher using Remote Control Instruction to the many protocols and networks
available. The driver supports one to four ports that provide accessibility from one to four
independent serial networks.
1.1 General
Specifications
Ports: One to four ports to receive and/or transmit data
Receive buffer size: 255 bytes
Receive termination: Termination character
Receive database location: 0 to 7000
Communication Configuration
o Baud Rate: 300 to 115,200
o Parity: None, Odd, Even
o Data Bits: 5 to 8
o Stop Bits: 1 or 2
o RTS On and Off Timing: 0 to 65535 milliseconds
o Minimum Response Delay: 0 to 65535 milliseconds
o Hardware Handshaking: RTS/CTS
Supports device types of Topline VS/VO, “S” Series, and “E” Series
1.2 Resources
The ProLinx Communication Gateways, Inc. Startup Guide provides general information on all
ProLinx modules including installation, editing configuration files, cabling and jumper
configurations, troubleshooting, and a wide range of useful information. You should have this
manual available when installing and configuring ProLinx modules.
ProLinx Communication Gateways, Inc.
3
06.PLNX.GRCM.OO.01.EN
July 2003