AN-X-TI-MAS Page

29

TIP

If you map the diagnostic data to a separate connection, use a long RPI
to reduce the Ethernet traffic, since the diagnostics do not need to be
updated as frequently as I/O data.

Examples:

, AnxTiDiag

2, AnxTiDiag ; mapped at offset 2

The diagnostic data consists of:

Range of offsets

Diagnostic data

0-15

Diagnostic counters

20-35

Base module fault table

40-55

Base status table

60-75

Dual power supply status table

80-240

Update time tables for ControlLogix connections

Diagnostic Counters.

Offset

Counter Description

0

Transmitted network frames

1

Received frames with good status

2

Received frames with a CRC error

3

Received frames with an abort error

4

Received frames with noise errors

5

Receive timeout. Scanner sent a message to a
base but did not receive a reply within the
timeout period

6

Received frames too short

7

Received frames too long

8

Received frames with protocol errors

9

Error type

10

I/O scan counter

11

I/O inits. The number of times the I/O