MVI69-GSC ♦ CompactLogix or MicroLogix Platform
Diagnostics and Troubleshooting
Generic ASCII Serial Communication Module
User Manual
ProSoft Technology, Inc.
Page 63 of 102
September 24, 2010
Viewing Module Configuration
Press [C]
to view the Module Configuration screen.
Use this command to display the current configuration and statistics for the
module.
Viewing Version Information
Press [V]
to view version information for the module.
Use this command to view the current version of the software for the module, as
well as other important values. You may be asked to provide this information
when calling for technical support on the product.
Values at the bottom of the display are important in determining module
operation. The Program Scan Counter value is incremented each time a
module’s program cycle is complete.
Tip: Repeat this command at one-second intervals to determine the frequency of program
execution.
Warm Booting the Module
Press [W]
from the Main menu to warm boot (restart) the module.
This command will cause the program to exit and reload, refreshing configuration
parameters that must be set on program initialization. Only use this command if
you must force the module to reboot.
Viewing Port Communication Status
Press [1]
or [2]
from the Main Menu to view the port communication status for
Ports 1 and 2.
Use this command to view communication status and statistics for the selected
port. This information can be informative when troubleshooting communication
problems.
Viewing Port Configuration
Press [6]
or [7]
from the Main Menu to view configuration information for ports 1
and 2.
Use this command to display detailed configuration information for the selected
port.
Exiting the Program
Press [ESC]
to restart the module and force all drivers to be loaded. The module
will use the configuration stored in the module's Flash memory to configure the
module.