3.1

Adding the Module to an Existing CompactLogix Project

Important: The following steps describe how to install and configure the MVI69-GSC module with
RSLogix 5000 version 15 or older. If you are using RSLogix 5000 version 16, please refer to
Sample Add-On Instruction Import Procedure (page 18).
Important: The MVI69-GSC module has a power supply distance rating of 2 (L43 and L45
installations on first 2 slots of 1769 bus)


If you are installing and configuring the module with a CompactLogix processor,

follow these steps. If you are using a MicroLogix processor, refer to the next

section.
1 Add the MVI69-GSC module to the project. Right-click the mouse button

on the I/O Configuration option in the Controller Organization window to

display a pop-up menu. Select the New Module option from the I/O

Configuration menu.