7.1 General
Item
Explanation
First Digit Time Out
Specify the duration of the first digit to be dialed when the FXO
port was OFF Hook. The range is 1~60 sec.
Inter Digit Time Out
Specify the interval of entering between two digits. If the interval
setting time is expired, the gateway sends out the DTMF digits
immediately. The time range is 1~10 sec.
End of Digit
The assigned key was treated as end of dial and dial out
immediately.
Retrieve Number
It forces the line to retrieve back if VIP-400 series makes a
transfer call to 3rd party but it DOES NOT answer and put this
call go into voice mail service. You can press the preprogram
code to retrieve back this call from transferred 3
rd
party. Default
code is “*#”.
7.2 Dialing Rule
Dialing rule is used to speed up the dialing procedure. Some users don’t like to use the end of dialing
digit such as “#”, the administrator can use dialing rule instead. The longest prefix will be matched first.
50