beautypg.com

3 ica-hm830 installation – PLANET ICA-HM830W User Manual

Page 6

background image

6

Terminal block for I/O connectors:

Name

Pin

Function

GND

1

Four sets of Digital Input, DI1 until DI4; the internal
device is also photo-coupled electrical relay. In practice,
the external device can be simply an On/Off switch.
Four sets of On/Off switch can be connected as different
trigger source.

Digital input 4

2

Digital input 3

3

Digital input 2

4

Digital input 1

5

DO_NO

6

Digital output implementation; Pin6 to COM (Pin7) is a
Photo-coupled relay on Normal Open status. External
device can directly connect to the terminals. However the
current that will go through the 2 nodes must not exceed
130mA. An external “Relay” can also be connected to the
terminals as an implementation. In this case, current (or/
and voltage) limitation is specified by the external Relay.

DO_COM

7

2.1.3 ICA-HM830 Installation