3 physical installation – PLANET ICA-310 User Manual
Page 14
1
1. RJ-45 LAN socket: Connect to PC or Hub/Switch. For connect to 10Base-T Eth-
ernet or 100Base-TX Fast Ethernet cabling. This Ethernet port built N-Way pro-
tocol can detect or negotiate the transmission speed of the network automati-
cally. Please use Category 5 “straight through” cable to connect the ICA-525 to a
100Mbps Fast Ethernet network switch or hub.
Note
In case you need to connect the device to PC or notebook directly,
you should use cross over cable instead.
2. RS-485 & DI/DO: Connect to a local keyboard controller and connect to sensor
in and alarm out devices
Inside the TEL box:
Name
Function
12VDC
DC 12V output (50mA maximum)
GND
GND
D+
RS485 data +
D-
RS485 data -
DI
Digital signal input
DO
Digital signal output
Note
The RS-485 of ICA-525 is master that can control external scanner.
3. Local Video output (BNC port): The Network Camera also provides composite
video output. User can use BNC video cable to connect the Network Camera
with a TV monitor or VCR.
4. DC-in Jack: The input power is 12VDC. Note that supply the power to the Net-
work Camera with standard power adapter included in package. Otherwise, the
improper power adapter may damage the unit and result in danger.
5. Line in (audio in): Connect an audio input source to the ICA-525.
6. Line out (audio out): Connect a loud speaker to the ICA-525. This function is for
voice alerting and two-way audio.
6.3 Physical Installation
1. Use the provided L-wrench, loosen the tamper-resistant housing cover (with