User’s Manual of BSP-300
11
Max. solar array Voc
60VDC
Max. operating voltage
45VDC
Total current consumption
While operating ‐32mA
At idle ‐11mA
High temperature shutdown
100 Degree C disconnect solar and load
80 Degree C reconnect solar and load
Overload Capacity
Over 15 Amp will cut off output load
Battery Charging Characteristics
Charge algorithm
Bulk charge (constant current), Absorption charge (constant
voltage) and Floating charge. Absorption and Floating charge with
PWM protection.
Maximum output current
15A
Nickel‐cadmium battery
± 40 mV/Degree Celsius for NiCad type batteries, Charge cut‐off
@ 55 Degree C
(Temperature compensation Baseline@ 25 Degree C)
Lead‐acid battery
(Default Setting)
± 60 mV/Degree Celsius for lead acid type batteries, Charge
cut‐off @ 55 Degree C
(Temperature compensation Baseline@ 25 Degree C)
Float charge voltage
DC 27.2V ( 26.0~30.0V )
Absorption charge voltage
DC 29.2V ( 28.0~32.0V )
LVD
(Low Voltage Disconnection)
DC 22.2V ( 21.0~25.0V )
LVR
(Low Voltage Reconnection)
DC 24.8V ( 23.0~27.0V )
Standards Conformance
Computer Interface
IEEE 802.3 10Base‐T
IEEE 802.3u 10/100Base‐TX
IEEE 802.3ab 10/100/1000Base‐T
IEEE 802.3at / 802.3af for PoE (Power over Ethernet) devices
Regulation Compliance
CE, FCC