beautypg.com

Section 6 – EFJohnson SMARTZONE 7780 User Manual

Page 77

background image

6-1

November 1999

Part No. 001-7780-500

ALIGNMENT PROCEDURE AND PERFORMANCE TESTS

SECTION 6 ALIGNMENT PROCEDURE AND PERFORMANCE TESTS

6.1 GENERAL

6.1.1 INTRODUCTION

The alignment procedure described in this section

should be performed if repairs are made that could
affect the factory alignment. In addition, before a
transceiver is initially placed in service, the perfor-
mance tests in Sections 6.8 and 6.9 should be
performed.

To perform the alignment described in this

section, special PCTune software (see Table 1-1) and
the same basic computer setup used for programming
is required. This equipment is shown above and also
described in Section 3.1. Only Remote Programming
Interface (RPI), Part No. 023-9800-000, can be used
because it is the only RPI that has microphone and
speaker audio jacks that are required for alignment.

Only two adjustments are made manually and the

others are made digitally using the PCTune software.
The two manual adjustments are squelch sensitivity
and TCXO frequency, and if they do not need to be
reset, the transceiver can be tuned without removing
the cover.

This transceiver does not have a special test mode

that is selected. The PCTune software automatically
selects the frequencies and other test conditions that
are required to perform the alignment. If the trans-
ceiver must be controlled manually to perform such
things as testing or troubleshooting, program tempo-
rary conventional channels.

6.1.2 TEST SETUP

Connect the test setup shown in Figure 6-1. Addi-

tional information follows on equipment in this setup.

Figure 6-1 Alignment Setup Diagram

Remote Programming Interface (RPI)

Signal Generator/

Wattmeter

50-ohm

Load

Comm. Monitor

Generator

Audio

PC-Compatible

Computer

Speaker Load

Part No. 023-9800-000

RPI-Transceiver Cable

Part No. 597-2002-123

680-Ohm