Register 2ch subsystem vendor id (ssvid) read only – Avago Technologies LSI53C810AE User Manual
Page 4

4
Configuration Register Changes
for
SYM53C810AE
Register 2Ch
Subsystem Vendor ID (SSVID)
Read Only
SVID
SVID
SVID
SVID
15-12
11-8
7-4
3-0
Default>>>
1
0
0
0
This register supports subsystem identification, which has a default value of 1000h in the
SYM53C810AE.
Register 2Eh
Subsystem ID (SSID)
Read Only
SID
SID
SID
SID
15-12
11-8
7-4
3-0
Default>>>
1
0
0
0
This register supports subsystem identification, which has a default value of 1000h in the
SYM53C810AE.
Register 06h
Status
Read/Write
DPE
SSE
RMA
RTA
RES
DT
DPR
RES
NC
RES
15
14
13
12
11
10-9
8
7-5
4
3-0
Default >>>
0
0
0
0
0
0
0
0
1
0
Reads to this register behave normally. Writes are slightly different in that bits can be cleared,
but not set. A bit is reset whenever the register is written and the data in the corresponding bit
location is a one. For instance, to clear bit 15 and not affect any other bits, write the value 8000h
to the register.
Please note the following changes to Register 06h bits 7-0.
Bits 7-5 Reserved
Bit 4 New Capabilities (NC)
This bit is set to indicate the presence of a list of extended capabilities such as PCI Power
Management. This bit is Read Only.
Bits 3-0 Reserved