A.3.8 list, A.3.8.1 command line, A.3.8.2 parameters – Avago Technologies SAS 9300-4i Host Bus Adapter User Manual
Page 38: A.3.8.3 program return value, A.3.8.4 sample output, List

LSI Corporation
- 38 -
SAS-3 Integrated RAID Solution User Guide
November 2012
Appendix A: Using the SAS-3 Integrated RAID Configuration Utility
Commands
Volume state : Optimal
Volume wwid : 054f59a844a86682
Physical disk I/Os : Not quiesced
Volume size (in sectors) : 285155328
Number of remaining sectors : 283997632
Percentage complete : 0.41%
IR Volume 2
Volume ID : 323
Current operation : None
Volume status : Enabled
Volume state : Optimal
Volume wwid : 0e2ca3c68dc5dc20
Physical disk I/Os : Not quiesced
SAS3IRCU: Command STATUS Completed Successfully.
SAS3IRCU: Utility Completed Successfully.
The possible values for the fields in the status data are as follows:
Current operation: Synchronize, Consistency Check, OCE, Background Init, or None
Volume status: Enabled or Disabled
Volume state: [Inactive] Optimal, Degraded, Missing, or Failed
Physical disk I/Os: Quiesced or Not quiesced
A.3.8
LIST
The LIST command displays a list of all controllers present in the system, along with each corresponding controller
index. You need the controller index as an input parameter for other SAS3IRCU commands.
A.3.8.1
Command Line
sas3ircu list
A.3.8.2
Parameters
None.
A.3.8.3
Program Return Value
0x00
SUCCESS: Command completed successfully.
0x01
FAILURE: Command failed.
0x02
ADAPTER_NOT_FOUND: Cannot find specified adapter.
A.3.8.4
Sample Output
Following is an example of the output of the LIST command. The format and fields in the output vary depending on
the types of installed controllers.
Adapter Vendor Device
SubSys SubSys
Index Type ID ID Pci Address Ven ID Dev ID
----- --------- ------ ------ ---------------- ------- ------
0 SAS3008 1000h 72h 00h:01h:00h:00h 1000h 00dah
1 SAS3008 1000h 72h 00h:05h:00h:00h 1000h 00dah