Appendix A: Using the SAS-3 Integrated RAID Configuration Utility

Commands

A.3.4.2

Parameters

<controller_#> – The index of the controller with the volume or volumes that you want to delete.

<volumeID> – The volumeID of the specific IR volume that you want to delete.

[noprompt] – This optional parameter prevents warnings and prompts from appearing while the command is
running.

A.3.4.3

Program Return Value

0x00

SUCCESS: Command completed successfully.

0x01

FAILURE: Bad command-line arguments or operational failure.

0x02

ADAPTER_NOT_FOUND: Cannot find specified adapter.

A.3.5

DISPLAY

The DISPLAY command displays information about LSI SAS-3 controller configurations, including controller type,

firmware version, BIOS version, volume information, physical drive information, and enclosure. See the following
sample output example.

The physical device information section displays the duplicate device of a dual-port SAS drive.

A.3.5.1

Command Line

sas3ircu <controller_#> display [filename]

A.3.5.2

Parameters

<controller_#> – The index of the controller for which you want to display information.

[filename] – An optional valid filename to store the command output to a file.

A.3.5.3

Program Return Value

0x00

SUCCESS: Command completed successfully.

0x01

FAILURE: Bad command-line arguments or operational failure.

0x02

ADAPTER_NOT_FOUND: Cannot find specified adapter.

A.3.5.4

Sample Output

Following is a sample of the information that the DISPLAY command returns.

Read configuration has been initiated for controller 0
------------------------------------------------------------------------
Controller information
------------------------------------------------------------------------
Controller type : SAS3008
PI Supports : Yes
PI Mixing : Enabled
BIOS version : 7.00.02.00
Firmware version : 00.250.19.0
Channel description : 1 Serial Attached SCSI
Initiator ID : 112
Maximum physical devices : 62
Concurrent commands supported : 266
Slot : 3
Segment : 0
Bus : 64
Device : 1