MegaRAID SAS Device Driver Installation User Guide

June 2014

XenServer Driver Installation

Installing or Updating the XenServer 6.0, 6.1, or 6.2 OS Driver

17. Choose the time zone from the displayed list of geographical areas, then click OK to proceed.

You are prompted to choose a method for setting the system time. The options are Using NTP or Manual time.

18. Select Using NTP.

You are prompted for the IP address and the gateway.

19. Use the default setting, and click OK to continue.

From this point forward, the installation begins to copy files to hard drive, and a progress bar appears.

20. For Xenserver 5.6.0 DUD installations only, perform the following steps:

Towards the end of the installation process, the installer prompts you for any additional packages. The
megaraid_sas

driver RPM listed is listed as a selection.

a.

Before you select the megaraid_sas driver RPM, insert the pen drive into the USB slot, and then select
Accept and continue as normal.

If you are installing the Xenserver 5.5.0 OS, remove the pen drive when the installation process begins.

b.

After the installation completes, select Reboot.

The system now runs under the Citrix Xenserver OS.

9.3

Installing or Updating the XenServer 6.0, 6.1, or 6.2 OS Driver

Perform the following steps to install or update to the latest version of the MegaSAS driver:

1.

Boot the system.

2.

Go to Console (your terminal GUI).

3.

Install the Dynamic Kernel Module Support (DKMS) driver RPM.

Uninstall the earlier version first, if needed.

4.

Install the MegaSAS driver RPM.

Uninstall the earlier version first, if needed.

5.

Reboot the system to load the driver.