beautypg.com

Avago Technologies Cache Protection for RAID Controller Cards User Manual

Page 9

background image

LSI Corporation

- 9 -

MegaRAID CacheVault Flash Module 02 Quick Installation Guide
March 2012

MegaRAID CacheVault Flash Module 02 Quick Installation Guide

Attaching the CVFM02 Module to a RAID Controller and Connecting It to a CVPM02 Module

on a Remote Mount Board

Reinstalling the MegaRAID SAS 9266-8i RAID Controller on the Motherboard

Follow these steps to reinstall the CVFM02 module on a motherboard.

1.

With the power to the chassis still turned off and the power cords unplugged, make sure that the chassis is
grounded and has no AC power.

2.

Install the RAID controller in a PCI Express slot on the motherboard, as shown in the following figure.

3.

Press down gently, but firmly, to seat the card correctly in the slot.

4.

Secure the controller to the computer chassis with the bracket screw.

Figure 6 Reinstalling the MegaRAID SAS 9266-8i RAID Controller

NOTE Some PCI Express slots support only PCI Express graphics cards; if a RAID controller is installed in
one of these slots, the controller will not function. Refer to your computer documentation for information
about the PCI Express slot.

Edge of

Motherboard

PCI Express

Bracket
Screw

Press

Here

Press

Here

3_00899-00

This manual is related to the following products: