Avago Technologies Cache Protection for RAID Controller Cards User Manual
Page 8

LSI Corporation
- 8 -
MegaRAID CacheVault Flash Module 02 Quick Installation Guide
March 2012
MegaRAID CacheVault Flash Module 02 Quick Installation Guide
Attaching the CVFM02 Module to a RAID Controller and Connecting It to a CVPM02 Module
on a Remote Mount Board
Connecting the CVFM02 Module to the Remote CVPM02 Module
Follow these steps to connect the CVFM02 module on the MegaRAID SAS 9266-8i RAID controller by cable to the
remote CVPM02 module.
1.
Make sure the remote mount board is on a flat, clean, static-free surface. Ground yourself, and make sure that the
system is grounded.
2.
Remove the cable that is included in the RAID controller box.
3.
Insert the smaller of the two 6-pin cable connectors on the cable into the 6-pin J2B1 cable connector on the
CVFM02 module, as shown in the following figure.
4.
Insert the larger of the two 6-pin cable connectors on the other end of the cable into the 6-pin cable connector on
the remote CVPM02 module.
5.
Align the cable connectors to make sure that they are connected correctly.
Figure 5 Connecting the CVFM02 Module on the RAID Controller to the Remote CVPM02 Module
3_00894-00
J2B1