The following symbols and values are displayed – Amprobe PQ55A Power-Analyzer User Manual
Page 10

The multi-function display contains the currently measured primary quantities.
The display format and the units (V, kV, A, kA, W, kW, MW etc...) are automati-
cally displayed in compliance with the selected values.
The following symbols and values are displayed:
5.1
0
Auto-power-off function is activated
5.2
P1 Display of the active power on phase 1
P2 Display of the active power on phase 2
P3 Display of the active power on phase 3
Pt Display of the total active power
5.3
HOLD] Activated HOLD fonction
5.4
Display value for active power
5.5
Unit of the active power: kW or Unit of the energy: kWh or MWh
5.6
Unit of the idle power: kvar or Unit of the energy: kvarh or Mvarh
5.7
Display value for idle power
5.8
Q1 display of the idle power on phase 1
Q2 display of the idle power on phase 2
Q3 display of the idle power on phase 3
Qt Display of the total idle power
☞
A negative sign “- “ indicates a leading current.
5.9
DATA No.xx Display of the storage place. Manual data memory: display of
the last saved manual measurement value (01 through 99)). Data logger:
display of the last saved series of measurements (01 through 10)
☞
Maximum 10 series of measurements or 21.000 measurement values
can be saved.
• If “FF“ is displayed, the data memory is full.
• If “00“ is displayed, the data memory is empty.
5.10
M] display for active saving process
☞
The symbol [M] is briefly displayed for manual measurement data saving.
• The symbol is permanently displayed for active data logger recording and
is briefly hidden during automatic saving.
[R] display of individually saved measurement values
DATA [R] No. xx display of the storage place for the measurement value
5.11
1P2W single-phase power measurement
1P3W two-phase power measurement
P3W2M three-phase power measurement, Aron connection
3P4W three-phase power measurement, start connection
5.12
PF1 –power factor display on phase 1
PF2 power factor display on phase 2
PF3 power factor display on phase 3
PFt –display of the total power factor
☞
A negative sign “- “ indicates a leading current.
5.13
Display value of additional display
5.14
[LOCK] keyboard lock is active
5.15
[BT] display for used batteries
5.16
display of phase angle ° unit of phase angle
5.17
display of the current measured via input “I4”
5.18
unit of the current
5.19
unit of the frequency
5.20
unit of the apparent power: kVA or unit of the energy: kVAh or MVAh
5.21
display value of apparent power
5.22
S1 display of apparent power on phase 1
S2 display of apparent power on phase 2
S3 display of apparent power on phase 3
St display of the total apparent power
5.23
U1 or U12 display of voltage on phase 1 (U1) or the conductor voltage U12
5.24
Y-M display for year (Y) and month (M)
10