Emerson MICRO MOTION 1700 User Manual
Page 10

The transmitter's model number is on a tag on the side of the transmitter. You can use the
model number to determine the transmitter's output option. The first four characters are
the transmitter type. The fifth character is the installation type. The eighth character is the
output option. The remaining characters are not relevant to transmitter installation.
Model code identification
Figure 1-7:
Transmitter type
Installation type
Output option
Installation types for Model 1700 and Model 2700 transmitters
Table 1-2:
Letter
Description
R
Remote mount 4-wire
I
Integral
C
Remote mount 9-wire (painted aluminum housing)
B
Remote core processor with remote transmitter
M
Remote mount 4-wire (stainless steel housing)
P
Remote mount 9-wire (stainless steel housing)
Output options for Model 1700 and Model 2700 transmitters
Table 1-3:
Letter
Description
A
Analog outputs – one mA, one frequency, one RS-485
B
Configurable I/O channels (default configuration of two mA, one frequency)
C
Configurable I/O channels (custom configuration )
D
Intrinsically safe analog outputs – two mA, one frequency/discrete
E
Intrinsically safe Foundation fieldbus H1 with standard function blocks
G
PROFIBUS-PA
N
Non-incendive Foundation fieldbus H1 with standard function blcoks
2
WirelessHART – one mA, one frequency, one RS-485
3
WirelessHART – one mA, two configurable I/O channels (custom configura-
tion)
4
Intrinsically safe WirelessHART – two mA, one frequency
Planning
6
Micro Motion
®
Model 1700 and 2700