Wire gauge calculation chart, Maximum current draw through the wire w ire gauge, Button decal plate – Whelen HHS2200 User Manual
Page 6
Page 6
Button 6 - This button activates Outlets 4 and 5. This button cycles in the
following manner:
1st Press - Activates Outlet 4
2nd Press - Activates Outlet 5
3rd Press - Activates Outlets 4 & 5
4th Press - Deactivates Outlets 4 & 5
Button 7 - This button activates Outlet 6.
Button 8 - This button activates Outlet 7.
Button 9 - This button activates Outlet 8.
Multi-Function Deactivation - To turn off all active operations, press and
hold any active keypad button for at least 2 seconds.
Dip Switch Functions
The amp/relay module contains a bank of 4 dip switches. The function of
each switch is as follows:
DS1 - This dip switch must remain in the ON position at all times.
DS2 - This switch determines the audio characteristics of the WAIL siren
tone. If the DS2 is in the OFF (default) position, an ‘electronic’ siren tone
will be generated. If DS2 is in the ON position, a simulated ‘mechanical’
siren tone will be generated.
DS3 - This switch controls the siren pursuit tone. If DS3 is in the ON
position, the WAIL tone is generated when button 3 is pressed. If DS3 is in
the OFF position, no siren tone is generated when button 3 is pressed.
DS4 - This switch determines the method that will be used to turn the siren
system on. If the switch is in the ON position, the system is turned on by
switching the high-current main power lines (1-3 & 1-4). If this is desired, a
switch sized to handle the entire current load must be installed in-line with
both 1-3 and 1-4.
If the DS4 is in OFF position, the system is turned on via the LCPA wire (5-
3 or 5-8).
NOTE: The controller is shipped without any button decals installed.
Do not place button decals directly onto the buttons. Install a plate
onto each button first and then adhere the desired button decal onto
that plate.
Programing
The button functions of the controller may be reprogramed using the HHS
2200 Plus Configuration software. The amp/relay module must first be
connected to the programing computer via the USB Port.
Refer to the online help provided with the software for programming
procedures.
Wire Gauge Chart
5 Amps
55 Amps
10 Amps
60 Amps
15 Amps
65 Amps
20 Amps
70 Amps
25 Amps
75 Amps
30 Amps
80 Amps
35 Amps
85 Amps
40 Amps
90 Amps
45 Amps
95 Amps
50 Amps
100 Amps
6 Feet
3 Feet
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
22 AWG
20 AWG
18 AWG
16 AWG
14 AWG
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
2 AWG
9.5 Feet
5 Feet
3 Feet
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
15 Feet
7.5 Feet
5 Feet
4 Feet
3 Feet
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
24.5 Feet
12 Feet
8 Feet
6 Feet
5 Feet
4 Feet
3.5 Feet
3 Feet
Insufficient
Insufficient
39 Feet
19.5 Feet
13 Feet
9.5 Feet
8 Feet
6.5 Feet
5.5 Feet
5 Feet
4.5 Feet
4 Feet
62 Feet
31 Feet
20.5 Feet
15.5 Feet
12.5 Feet
10.5 Feet
9 Feet
7.5 Feet
7 Feet
6 Feet
98 Feet
49 Feet
32.5 Feet
24.5 Feet
19.5 Feet
16.5 Feet
14 Feet
12.5 Feet
11 Feet
10 Feet
156 Feet
78 Feet
52 Feet
39 Feet
31 Feet
26 Feet
22.5 Feet
19.5 Feet
17.5 Feet
15.5 Feet
248.5 Feet
124 Feet
82.5 Feet
62 Feet
49.5 Feet
41.5 Feet
35.5 Feet
31 Feet
27.5 Feet
25 Feet
395 Feet
197.5 Feet
131 Feet
98.5 Feet
79 Feet
66 Feet
56.5 Feet
49.5 Feet
44 Feet
39.5 Feet
629 Feet
314 Feet
209 Feet
157 Feet
125.5 Feet
104.5 Feet
89.5 Feet
78.5 Feet
69.5 Feet
63 Feet
Maximum Current Draw Through The Wire
W
ire
Gauge
22 AWG
20 AWG
18 AWG
16 AWG
14 AWG
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
2 AWG
Maximum Current Draw Through The Wire
W
ire
Gauge
Wire Gauge Calculation Chart
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
Insufficient Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
3.5 Feet
3 Feet
3 Feet
3 Feet
Insufficient Insufficient
Insufficient
Insufficient
Insufficient
Insufficient
5.5 Feet
5 Feet
5 Feet
4.5 Feet
4 Feet
4 Feet
3.5 Feet
3.5 Feet
3.5 Feet
3 Feet
9 Feet
8 Feet
7.5 Feet
7 Feet
6.5 Feet
6 Feet
6 Feet
5.5 Feet
5 Feet
5 Feet
14 Feet
13 Feet
12 Feet
11 Feet
10.5 Feet
10 Feet
9 Feet
8.5 Feet
8 Feet
8 Feet
22.5 Feet
20.5 Feet
19 Feet
17.5 Feet
16.5 Feet
15.5 Feet
14.5 Feet
14 Feet
13 Feet
12.5 Feet
36 Feet
33 Feet
30.5 Feet
28 Feet
26.5 Feet
24.5 Feet
23 Feet
22 Feet
21 Feet
19.5 Feet
57 Feet
52.5 Feet
48.5 Feet
45 Feet
42 Feet
39 Feet
37 Feet
35 Feet
33 Feet
31.5 Feet
Button
Decal
Plate