Siren Scan-Lock Switch
20 AMP FUSE
Rear view of Amplifier
Relay
Scan-Lock™
Switch
TABLE 7
Override Tone List For Rotary
Switch Position: RAD
TONE OFF
.
AIRHORN
.
TONE OFF
MANUAL WAIL STOP
M
TABLE 6
Tone List For MAN1 & MAN2:
..
.
MANUAL WAIL COAST-TO-STOP
Programming the Epsilon™ 2S9 Siren:
Slide Switch Programming:
The Epsilon™ 2S9 has the ability to reconfigure the slide switch so that
any of the three active switch positions can activate any combination of
the relay outputs.
WARNING: Never try to program the siren while it is wired to the
vehicle. The siren must be removed from the vehicle before
programming. A low level audio device is built into the siren so that
siren tones can be heard during programming. For programming,
connect positive (+) battery and ground only.
To Configure the Slide Switch’s Outputs:
1.
Remove the cover of your Epsilon™ 2S9 by removing the 4 screws
on the sides of the unit.
2.
Place the slide switch in the position you wish to reconfigure. The
indicators will display the active position of the slide switch.
3.
Press and release the Scan-Lock™ switch located on the relay
board. (The indicators will now display the wire colors of the relay
outputs programmed to activate in this position)
4.
Continue to Press and release the Scan-Lock™ switch to cycle
through the relay outputs. Stop when the indicator lights equal the
desired output pattern.
5.
Return the Slide Switch to the off position. (The output pattern for that
lever position has now been saved.)
To configure other switch positions, start at step 2.
Siren Tone Programing Procedures:
With Scan-Lock™
the tonal operation
of the siren can be
customized to fit
your needs. Scan-
Lock™ is used to
change the default
siren tones as
shown below. The
Siren Scan-Lock™
switch is located in
the rear of the unit.
To change the primary tone for rotary switch
positions T1, T2, & T3: Put the rotary switch in
the position that you wish to change. Press and
release the Scan-Lock™ switch. Each time the
Scan-Lock™ switch is pressed and released, the
next available tone will be broadcast. When the
desired tone is generated, it is automatically
saved for that rotary switch position.
To change the override tone for rotary switch
positions T1, T2. & T3: Put the rotary switch in
the position that you wish to change. Press and
hold the MAN button on the front panel on the
siren. Press and release the Scan-Lock™ switch.
Each time the Scan-Lock™ switch is pressed and
released, the next available tone will be
broadcast. When the desired tone is present, it
will automatically be saved as the override tone for that rotary switch
position. Release the MAN button.
To change one of the tones in the hands free
cycle. (See “Hands Free Operation”): Put the
rotary switch in the HF position. Using the MAN
button on the front panel on the siren, advance to
the tone that you wish to change. Press and
release the Scan-Lock™ switch. Each time the
Scan-Lock™ switch is pressed and released, the
next available tone will be broadcast. When the desired tone is generated,
it will automatically be saved for that hands-free cycle position.
To change the tone for rotary switch positions
MAN1 or MAN2:
Put the rotary switch in the position that you wish
to change. Press and hold the MAN button on the
front panel on the siren. Press and release the
Scan-Lock™ switch. Each time the Scan-Lock™
switch is pressed and released, the next available tone will be broadcast.
When the desired tone is generated, it will automatically be saved for that
rotary switch position. Release the MAN button.
To change the override tone for rotary switch
position RAD:
Put the rotary switch in the RAD position. Press
and hold the MAN button on the front panel on
the siren. Press and release the Scan-Lock™
switch. Each time Scan-Lock™ is pressed and released, the next
available tone will be broadcast. When the desired tone is generated, it
will automatically be saved for that rotary switch position. Release the
MAN button.
Title 13 Operation:
Airhorn will not override primary tones. To put the siren into Title 13
operation mode:
1.
Turn the POWER switch OFF.
3.
Place the ROTARY SWITCH into the MAN1 position.
4.
Hold Scan-Lock™ switch in while turning power on. A set
of Title 13 compliant tones have been programmed for use.
Turn power off, then on to activate changes.
Re-Setting Factory Defaults:
To restore siren tones to the factory defaults:
1.
Turn the POWER switch OFF.
3.
Place the ROTARY SWITCH into the MAN2 position.
4.
Hold Scan-Lock™ switch in while turning power on.
Turn power off, then back on to activate the changes.
Epsilon™ 2S9 Specifications:
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.8 VDC ±20%
Input Current . . . . . . . . . . . . . . . @15 VDC @ 5.5 OHMS16 AMPS MAX.
Input Fuse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 AMPS
Speaker Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 OHMS MIN.
Operating Temperature . . . . . . . . . . . . . . . . . . . . . . . -30° C. TO +60° C.
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . -40° C. TO +70° C.
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99% (NON CONDENSING)
Output Voltage . . . . . . . . . . . . . @ 15 VDC @ 11 OHMS 34 V RMS MAX.
Output Power . . . . . . . . . . . . @ 15 VDC @ 11 OHMS 105 WATTS MAX.
Lighting Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 AMPS MAX
Relay Outlets . . . . . . . . . . . 20 AMPS MAX / 50 AMPS COMBINED MAX
WAIL
YELP
PIERCER
TABLE 5
Tone List For Hands Free:
..
.
= Title 13 Compliant Tones
*
*
PIERCER
Y-249
HI/LOW
..
.
= Title 13 Compliant Tones
*
*
TABLE 4
Override Tone List For Rotar
Switch Positions T1, T2 & T3
y
TONE OFF
WAIL
YELP
..
.
HI/LOW
PIERCER
Y-249
..
.
AIRHORN
.
= Title 13 Compliant Tones
*
*
TONE OFF
WAIL
YELP
TABLE 3
y
Tone List For Rotar Switch
Positions T1, T2 & T3
..
.
HI/LOW
PIERCER
Y-249
..
.