background image

Page 5

off

off

off off

SWITCH 9 CAN TO OPERATE IN 4 DIFFERENT MODES,

DEFINED BY THE 4 POSITION DIP SWITCH

:

-

(Bank 4)

PANEL SWITCH 9

OPERATING MODE:

MOMENTARY

1 2 3 4

MODE 1 (DEFAULT)

PANEL SWITCH 9

OPERATING MODE:

8 SECOND ON TIMER

off

off

off

on

1 2 3 4

MODE 2

PANEL SWITCH 9

OPERATING MODE:

LATCH ON

LATCH OFF

off

off

off

on

1 2 3 4

MODE 3

PANEL SWITCH 9

OPERATING MODE:

FLASHER

(400MS ON & OFF)

off

off

off

on

1 2 3 4

MODE 4

ON

OFF

Down

(OFF)

Down

(OFF)

Down

(OFF)

Down

(OFF)

BANK 4

, -POSITION

DIP SWITCH CHART 4

Default (factory) setting shown.

Switch 9

(momentary)

1

ON

OFF

2

3

4

Custom Dip Switch Configuration (Dip Switch Bank 4):

Push-button 9 (momentary switch) can function in 4 different modes, defined by the 4-position dip switch bank 4.
This bank is located on top of the circuit board and is only accessible with the cover removed from the PCCS9NP.

Mode 1 - (default) - In this configuration, the output is activated for as long as push-button 9 is depressed.

Mode 2 - In this configuration, when push-button 9 is pressed, the output is activated for a period of 8 seconds.

Mode 3 - In this configuration, when push-button 9 is pressed, the output is activated. When pressed again, the
output is deactivated.

Mode 4 - In this configuration, when push-button 9 is pressed, the output is activated for a period of 400 ms. After
400 ms, the output is deactivated for 400 ms. This cycle will continue until push-button 9 is pressed again.

Enabling siren tones through slide switch pos. #3:

Slide switch position 3 can be configured to
automatically activate siren tones, as described in
“Rotary Switch Operations” (pg.6). If this is not desired,
make sure that dip switch #1 on bank 4 is in the off
position (the factory default position). Please note that
siren activation through slide switch position 3 is only