Bank 4 , -position dip switch chart 4, Page 5, Default (factory) setting shown – Whelen 295HFSA5 User Manual
Page 5
Page 5
off
off
off off
SWITCH 9 CAN TO OPERATE IN 4 DIFFERENT MODES,
DEFINED BY THE 4 POSITION DIP SWITCH
:
-
(Bank 4)
PANEL SWITCH 9
OPERATING MODE:
MOMENTARY
1 2 3 4
MODE 1 (DEFAULT)
PANEL SWITCH 9
OPERATING MODE:
8 SECOND ON TIMER
off
off
off
on
1 2 3 4
MODE 2
PANEL SWITCH 9
OPERATING MODE:
LATCH ON
LATCH OFF
off
off
off
on
1 2 3 4
MODE 3
PANEL SWITCH 9
OPERATING MODE:
FLASHER
(400MS ON & OFF)
off
off
off
on
1 2 3 4
MODE 4
ON
OFF
Down
(OFF)
Down
(OFF)
Down
(OFF)
Down
(OFF)
BANK 4
, -POSITION
DIP SWITCH CHART 4
Default (factory) setting shown.
Switch 9
(momentary)
1
ON
OFF
2
3
4
Custom Dip Switch Configuration (Dip Switch Bank 4):
Push-button 9 (momentary switch) can function in 4 different modes, defined by the 4-position dip switch bank 4.
This bank is located on top of the circuit board and is only accessible with the cover removed from the PCCS9NP.
Mode 1 - (default) - In this configuration, the output is activated for as long as push-button 9 is depressed.
Mode 2 - In this configuration, when push-button 9 is pressed, the output is activated for a period of 8 seconds.
Mode 3 - In this configuration, when push-button 9 is pressed, the output is activated. When pressed again, the
output is deactivated.
Mode 4 - In this configuration, when push-button 9 is pressed, the output is activated for a period of 400 ms. After
400 ms, the output is deactivated for 400 ms. This cycle will continue until push-button 9 is pressed again.
Enabling siren tones through slide switch pos. #3:
Slide switch position 3 can be configured to
automatically activate siren tones, as described in
“Rotary Switch Operations” (pg.6). If this is not desired,
make sure that dip switch #1 on bank 4 is in the off
position (the factory default position). Please note that
siren activation through slide switch position 3 is only
available when the power switch is in the ON position.