Configuring the Slide Switch Functions:

In the default dip switch setting, the P1 outputs are:
Slide Switch Positions:

Push-Buttons:

0 = Terminals OFF

4 = White / Black

1 = Green

5 = White

2 = Green / Grey

6 = Yellow

3 = Green / Grey / Blue

7 = Orange
8 = Black / White
9 = Violet

Changing Default Slide Switch Control:

Configuring Slide Switch Control:

The slide switch has four positions: 0 (off), 1, 2 & 3. When in position 0 (furthest to the left) the slide switch has not activated
any outputs. In position 1, 2 or 3 the slide switch can activate any combination of outputs 1 through 8. Each active slide
switch position uses a bank of dip switches to determine which outputs are to be active while the slide switch is in that
position; position 1 uses dip switch bank 1, position 2 uses dip switch bank 2, and position 3 uses dip switch bank 3.

Each dip switch bank is comprised of 8 switches, each representing a corresponding output (switch 1 for output 1, switch 2
for output 2, etc.). If, for example, switches 1, 3, 4 & 6 on dip switch bank 1 are in the ON position, outputs 1, 3, 4 & 6 will be
active when the slide switch is moved to position 1.

Slide switch configuration is as simple as deciding which outputs are to be active in a given position and then moving the
corresponding dip switch on the appropriate dip switch bank to the ON position.

1 - Slide Switch Output 1 (GRN)

2 - Slide Switch Output 2 (GRY)

3 - Slide Switch Output 3 (BLU)

4 - Switch 4 Output (WHT/BLK)

5 - Switch 5 Output (WHT)

6 - Switch 6 Output (YEL)

7 - Switch 7 Output (ORN)

8 - Switch 8 Output (BLK/WHT)

8

7

6

5

4

3

2

1

= OFF
= ON

Dip Switch

Bank 1

Dip Switch

Bank 4

Dip Switch

Bank 2

Dip Switch

Bank 3