0 introduction, 1 scope of manual, 2 description – KEPCO RCW 750W Series User Manual
Page 5: 0 specifications, Table 1. output ratings and specifications, Scope of manual, Description, Specifications

RCW 750W 120607
1
1.0 INTRODUCTION
1.1 SCOPE OF MANUAL
This Operator's Manual covers the installation and operation of the Kepco RCW 750W Series of
Switching Power Supplies. For service information, write directly to: Kepco Inc., 131-38 Sanford
Avenue, Flushing, New York, 11355, U.S.A. Please state Model Designation and Serial Number of
your RCW Power Supply. This information can be found on the nameplate of the unit.
1.2 DESCRIPTION
The Kepco RCW 750W Series consists of seven models of Switching Power Supplies, with a single
output as shown in Table 1. RCW power supplies are compliant with the Low Voltage Directive (LVD)
and carry the CE Mark. Units are designed to operate with a universal input voltage within the range
of 85 to 264V AC and may be operated with either 100-120V AC, or 200-240V AC (100 to 240 volts
nominal input range), 50-60 Hz (47-66 Hz) input. They will also operate on 125V to 370V dc input.
The RCW 750W Series employs a light weight ferrite core transformer with 160 KHz typical (140 KHz
typical for the RCW 48-15K model) switching frequency. The Power Factor Correction Circuit has a
typical switching of 60 KHz. Regulation is provided by pulse width modulation. A FET power stage,
operating in the forward conversion mode provides a smooth isolated dc output. A resistor and thyris-
tor "soft-start" circuit prevents excessive turn-on current surge. Overvoltage protection and optically
isolated remote TTL ON-OFF control are provided. Current limiting with automatic recovery from
short circuit is featured. Units are enclosed in a wrap-around aluminum case with a green LED "out-
put present" light visible on the terminal side of the case.
2.0 SPECIFICATIONS
Table 1 contains specifications and operating limits of individual RCW 750W Series models. Table
2 contains specifications and operating limits common to all RCW 750W Series Models. These
specifications are at nominal input voltages at 25°C unless otherwise specified.
TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS
MODEL RCW 750W
RCW 3.3-150K
RCW 5-150K RCW 12-62K RCW 15-50K RCW 24-31K RCW 28-26K RCW 48-15K
Output Volts d-c
(5)
3.3V
5V
12V
15V
24V
28V
48V
Adjustment Range
2.7~3.6
4.0~5.5
8.4~13.2
12.0~16.5
16.8~26.4
22.4~30.8
32.6~52.8
Maximum
Output
Ratings
(Amps,
Watts)
50°C, amb
150.0A
495.0W
150.0A
750.0W
62.5A
750.0W
50.0A
750.0W
31.3A
751.2W
26.8A
750.4W
15.7A
753.6W
60°C, amb
105.0A
346.5W
105.0A
346.5W
43.75A
525.0W
35.0A
525.0W
21.9A
525.84W
18.76A
525.28W
11.0A
527.52W
70°C, amb
60.0A
198.0W
60.0A
300.0W
25.0A
300.0W
20.0A
300.0W
12.52A
300.48W
10.72A
300.16W
6.28A
301.44W
Current Limit (Amps)
(1)
157 ~ 175
157~175
65.0~71.0
52.5~58.5
32.8~36.0
28.1~30.8
16.4~18.1
OVP Settings (Volts)
(2)
3.8 ~ 4.6
6.0~6.9
13.7~15.7
17.0~19.5
27.0~30.5
31.4~34.5
54.0~59.0
Efficiency
% typ
AC Input
120V
71
76
77
78
79
80
82
AC Input
240V
73
79
80
81
82
84
85
source(max)
20
20
20
20
20
20
20
Ripple &
Noise
(3)
(mV, p-p)
switching
(max)
50
50
80
80
120
120
200
spike noise
(max)
(4)
200
200
250
250
300
300
500
Transient
Recovery
(6)
Excursion
±V typ
1.0
1.0
0.5
0.5
0.5
0.5
0.15
Rec’y to
within 1%
(<µs)
100
100
75
75
50
50
500
1)
The Power Supply has a square type overcurrent characteristic, shutdown by undervoltage detection.
2)
The Power Supply has a shut-down type overvoltage characteristic. Recovery time to reset 40 seconds minimum.
3)
Source component 2x source frequency and switching component approximately 160 KHz, 10 to 100% load and ambient Ta = 25°C.
4)
Measure with a 50MHz bandwidth, 10 to 100% load and ambient Ta= 25°C.
5)
Output voltage setting = ±1%.
6)
A step load change from 50% to 100% of rated load current (with the following tr, tf load changes) produces no more than the output voltage excursions
listed in the above table; tr, tf of load change: 3.3V and 5V
≥
15
µs,
12V
≥
6.25
µs,
15V
≥
5
µs,
24V
≥
3.13
µs,
28V
≥
2.68
µs,
48V
≥
7.85
µs