MID-EFFICIENCY COUNTERFLOW / HORIZONTAL GAS FURNACE SPECIFICATIONS

5

Model NO.

MDA1-50

MDA1-75

MDA1-100

MDA1-125

Heat input rate (BTUH)

50,000 75,000 100,000

125,000

Heating capacity (BTUH)

1

40,000 60,000 81,000 101,000

Nominal temp. rise

70° F.

Heating fan speed

LOW MD

LOW LOW MD

LOW

Burner orifice size for nat. gas

0.0935” (#42)

Burner orifice size for L.P. gas

0.0591” (1.5 mm)

AFUE %

81.0 80.0 81.0 81.0

Height of casing

44-1/4”

Width of casing

17” 17” 17” 17”

Depth of casing

27 ½”

Warm air outlet

2

15” x 18”

15” x 18”

19” x 18”

22” x 18”

Return air inlet

2

15” x 18”

15” x 18”

19” x 18”

22” x 18”

Approx. shipping weight

131 LBS

143 LBS

170 LBS

186 LBS

Dia. of flue (vertical vent)

3” 4” 4” 4”

Dia. of flue (sidewall vent)

3

3” 4” 4” 4”

CFM @ .2” & .5” W.C. external
static pressure

.2”

.5”

.2”

.5”

.2”

.5”

.2’

.5”

@HI speed

900 730 1400 1220 1595 1370 2075 1790

@MH speed

835 680 1200 1075 1460 1260 1830 1605

@ML speed

- -

926

850

1360

1170

1620

1430

@LO speed

580 425 765 700 1220 1075

1345

1265

Blower motor type & frame

Permanent split capacitor, air over, 48 Y

Blower motor nominal HP

1/5 1/3 1/2 3/4

Blower motor full load amps

3.25 6.0 8.0 11.0

Motor shaft diameter

½”

Direction of rotation (shaft end)

Clockwise

No. of speeds

3 4 4 4

Run capacitor

10 mfd

370 VAC

10 mfd

370 VAC

10 mfd

370 VAC

15 mfd

440 VAC

Blower size

10-9 R DD

10-9 R DD

10-10 R DD

10-10 R DD

Size of filters

(2) –1” x 17 ¾” x

11 ¾”

(2) –1” x 17 ¾” x

11 ¾”

(2) – 1” x 17 ¾” x

13 ¾”

(2) – 1” x 17 ¾”

x 17 ¾”

Largest recommended air
conditioner

4

2 Ton

3 Ton

3.5 Ton

4 Ton

Electrical power requirements

115 volts, 60 Hz., 1 phase

Min. Fuse size

15 AMP

15 AMP

15 AMP

20 AMP

ACCESSORY ITEMS

Combustible Floor Base

50DA-BASE 50DA-BASE 100CA-BASE

125CA-BASE

Horizontal Plenum Angles

AOPS4942

Vent Kit (top vent option)

AOPS4941

NOTES:

1.

BTU output based on annual fuel utilization efficiency rated by manufacturer.

2. On all outlet and inlet dimensions, the first dimension is width.
3. The MHA1/MDA1 furnaces are approved for sidewall venting using only an approved sidewall power venter. Refer to Side

Wall Venting section of the Installation and service manual provided with the furnace for additional information.

4. To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is required.
5. All specifications are subject to change without notice.