beautypg.com

Accessory items – Thermo Pride Gas/Propane Furnace Induced Draft Highboy/Counterflow/Horizontal MHA1 User Manual

Page 59

background image

All installations and services must be performed by qualified service personnel.

56

APPENDIX G: MID-EFFICENCY FURNACE SPECIFICATIONS

MID-EFFICIENCY HIGHBOY GAS FURNACE SPECIFICATIONS

5

Model NO.

MHA1-50

MHA1-75

MHA1-100

MHA1-125

Heat input rate (BTUH)

50,000 75,000 100,000

125,000

Heating capacity (BTUH)

1

40,000 59,000 79,000 99,000

Nominal temp. rise

70°F

Heating fan speed

LOW LOW LOW LOW

Burner orifice size for nat. gas

0.0935” (#42)

Burner orifice size for L.P. gas

0.0591” (1.5 mm)

AFUE %

80.0 80.0 80.0 80.0

Height of casing

44-1/4”

Width of casing

17” 17” 21” 24”

Depth of casing

27 ½”

Warm air outlet

2

15” x 18”

15” x 18”

19” x 18”

22” x 18”

Return air inlet

2

25” x 16”

25” x 16”

25” x 16”

25” x 16”

Approx. shipping weight

131 LBS

143 LBS

170 LBS

186 LBS

Dia. of flue (vertical vent)

3” 4” 4” 4”

Dia. of flue (sidewall vent)

3

3” 4” 4” 4”

CFM @ .2” & .5” W.C. external
static pressure

.2”

.5”

.2”

.5”

.2”

.5”

.2’

.5”

@HI speed

950 830 1495 1335 1795 1560 2245 1970

@MH speed

860 740 1205 1125 1590 1410 1885 1710

@ML speed

- -

920

865

1410

1290

1605

1510

@LO speed

580 440 750 700 1240 1160

1350

1300

Blower motor type & frame

Permanent split capacitor, air over, 48 Y

Blower motor nominal HP

1/5 1/3 1/2 3/4

Blower motor full load amps

3.25 6.0 8.0 11.0

Motor shaft diameter

½”

Direction of rotation (shaft end)

Clockwise

No. of speeds

3 4 4 4

Run capacitor

10 mfd

370 VAC

10 mfd

370 VAC

10 mfd

370 VAC

15 mfd

440 VAC

Blower size

10-7 R DD

10-9 R DD

10-9 R DD

10-9 R DD

Size of filters

(1) – 1” x 24 ¾” x

15 ¾”

(1) – 1” x 24 ¾” x

15 ¾”

(1) – 1” x 24 ¾” x

15 ¾”

(1) – 1” x 24 ¾”

x 19 ¾”

Largest recommended air
conditioner

4

2 Ton

3.5 Ton

4 Ton

5 Ton

Electrical power requirements

115 volts, 60 Hz., 1 phase

Min. Fuse size

15 AMP

15 AMP

15 AMP

20 AMP

ACCESSORY ITEMS

Filter Rack
Flange dimensions

2

AOPS 7547

24-1/2” X 15”

AOPS 7547

24-1/2” X 15”

AOPS 7547

24-1/2” X 15”

AOPS 7375

24” X 19”

NOTES:

1.

BTU output based on annual fuel utilization efficiency rated by manufacturer.

2. On all outlet and inlet dimensions, the first dimension is width.
3. The MHA1/MDA1 furnaces are approved for sidewall venting using only an approved sidewall power venter. Refer to Side

Wall Venting section of the Installation and service manual provided with the furnace for additional information.

4. To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is required.

5.

All specifications are subject to change without notice.