Quickguide blower door, Show results as leakage area, Pressurization test – Retrotec Blower Door with DM-2 User Manual
Page 3: Adjust fan speed with gauge, Adjust fan speed remotely, Different results
Show results as leakage area
Equivalent Leakage Area (EqLA) describes the leakage
area in terms of one large hole in a flat surface.
□
Press [Mode] until “EqLA” appears.
“PrA” displays the building pressure and “EqLA” shows
the combined size of all the holes in the building.
Leakage area is not a required result, but is a nice
way to visualize the size of the hole in the house.
Tubing configuration is the same as for the
depressurization test.
QuickGuide Blower Door
CFM 50 is required in the
USA. The flow displayed is
what it would be at exactly
50 Pa, eliminating the need
for an exact test pressure.
Normalized leakage area
(m
3
/h·m
2
), required
in Europe.
Air Changes shown
directly on the gauge.
Display custom units.
e.g. units specified by
WA state.
Pressurization test
Turn the fan around to blow air into the house.
Adjust fan speed with gauge
Press [Exit] to turn the fan off.
Connect Speed Control Cable to fan.
Solid green Status light indicates DM-2 is connected.
Any test pressure can be entered. High test pressures
over 60 Pa are more likely to disturb building contents
and cause damage.
When speed or pressure is set, press [Jog/Hold] until
“Jog” appears, then [ ] [ ] to adjust up or down.
Click once to change by 1%, hold to increase by 5%.
Adjust fan speed remotely
Area and volume are input using the
[Enter] key.
Page 3 of 4
Page 2 of 4
Use optional remote speed control from up to 300 feet
away from fan.
The fan will accept any Set Speed from 1 to 100%.
Press [Set Speed] [50] [Enter] to set speed to 50%.
Press [Set Pressure] [25] [Enter] to get gauge to
control to a pressure of 25 Pa.
Different Results
Press [Mode] to access the available results, or use
[Setup] to access even more results. Some popular
options are shown below: