RISCO Group ProSYS Version 7.xx User Manual
Page 9
ProSYS Version 7.XX - Supplementary Instructions
9
Bus Zone Parameters: iWISE DT Grade 2
Quick Keys Parameter
Default
Range
[2][0][3][zz]
[5] [1] to [2]
Green Line Options
1) No - Green Line feature is disabled. MW is constantly activated.
2) Yes – Green Line feature is activated.
[2][0][3][zz]
[6]
Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a
Self Test Trouble is created.
[2][0][3][zz]
[6][1]
Remote (manual)
The remote self test is performed by the system when a user
manually selects the Diagnostics option from the Maintenance menu
via the ProSYS User Functions menu.
[2][0][3][zz]
[6][2]
Local (automatic)
Once an hour, the detector automatically checks that the detector’s
channels are functioning properly.
Bus Zone Parameters: iWISE DT AM Grade 3
Quick Keys Parameter
Default
Range
[2][0][3][zz]
[1]
LEDS
On
Defines the LEDS operation mode.
[2][0][3][zz]
[1] [1] to [2]
LEDS Options
1) Off - Disables the LEDS operation.
2) On – Enables the LEDS operation.
[2][0][3][zz]
[2]
MW (Microwave) Range
Trimmer
Defines the microwave channel range.
[2][0][3][zz]
[2] [1] to [7]
MW Range Options
1) Minimum 2) 25% 3) 50% 4) 65% 5) 85% 6) Maximum 7) Trimmer
(MW is defined by the trimmer setting on the PCB)
[2][0][3][zz]
[3]
ACT
No
Defines the Anti-Cloak™ Technology (ACT) operation mode.
[2][0][3][zz]
[3][1] to [2]
ACT Options
1) No - Disables the ACT mode.
2) Yes – Enables the ACT mode.