ProSYS Version 7.XX - Supplementary Instructions

9

Bus Zone Parameters: iWISE DT Grade 2

Quick Keys Parameter

Default

Range

[2][0][3][zz]
[5] [1] to [2]

Green Line Options

1) No - Green Line feature is disabled. MW is constantly activated.
2) Yes – Green Line feature is activated.

[2][0][3][zz]
[6]

Self Test

Remote

Used to test the detection technologies. In the event of a failed test, a
Self Test Trouble is created.

[2][0][3][zz]
[6][1]

Remote (manual)

The remote self test is performed by the system when a user
manually selects the Diagnostics option from the Maintenance menu
via the ProSYS User Functions menu.

[2][0][3][zz]
[6][2]

Local (automatic)

Once an hour, the detector automatically checks that the detector’s
channels are functioning properly.

Bus Zone Parameters: iWISE DT AM Grade 3

Quick Keys Parameter

Default

Range

[2][0][3][zz]
[1]

LEDS

On

Defines the LEDS operation mode.

[2][0][3][zz]
[1] [1] to [2]

LEDS Options

1) Off - Disables the LEDS operation.
2) On – Enables the LEDS operation.

[2][0][3][zz]
[2]

MW (Microwave) Range

Trimmer

Defines the microwave channel range.

[2][0][3][zz]
[2] [1] to [7]

MW Range Options

1) Minimum 2) 25% 3) 50% 4) 65% 5) 85% 6) Maximum 7) Trimmer
(MW is defined by the trimmer setting on the PCB)

[2][0][3][zz]
[3]

ACT

No

Defines the Anti-Cloak™ Technology (ACT) operation mode.

[2][0][3][zz]
[3][1] to [2]

ACT Options

1) No - Disables the ACT mode.
2) Yes – Enables the ACT mode.