RISCO Group ProSYS Version 7.xx User Manual
Page 13
ProSYS Version 7.XX - Supplementary Instructions
13
Bus Detector Naming Conventions
The following table contains the names of the various Bus detectors and their
corresponding Installer programming menu codes under the Type field, when
adding a new Bus zone to the system.
Bus Detector
TYPE Field Option
in Previous Versions
TYPE Field Option
in Version 7 and above
WatchOUT DT
ODT15
ODT15
WatchOUT PIR
OPR12
OPR12
Industrial LuNAR
LUNR
Cannot be selected,
Replaced by Industrial
LuNAR Grade 3.
Industrial LuNAR Grade 3
LUNG3
ILun3
WatchIN IDT25 WatIN
iWISE DT G2 Bus 15m,
25m
N/A
iDTG2
iWISE QUAD G2 Bus
N/A
iQDG2
iWISE DT G3 Bus 15m,
25m
N/A
iDTG3
iWISE QUAD G3 Bus
N/A
iQDG3
New Firmware Capabilities
The information in this section describes new capabilities in the ProSYS firmware
and new parameters under the Installer programming menu.
Tamper Test during Exit Programming
When exiting the Installer Programming menu, ProSYS will check if there are any
existing tamper faults in the system. A list of these tamper faults will appear. The
installer can select whether to confirm exiting the programming mode with a
tamper condition and by this a tamper alarm can occur or fix the tamper faults.
WatchOUT Proximity Anti Mask in WatchOUT extreme
WatchOUT DT version B (P/N RK325DT00xxB) has a new proximity anti masking
capability in addition to its improved IR anti masking capability.
When the WatchOUT DT is installed as a Bus zone, in order to enable Proximity
Anti-Mask the following parameters must be programmed:
Zones Miscellaneous: Bus Zone - WatchOUT
Quick Keys Parameter
Default
Range
[2][0][3][zz]
[8]
Prox Anti Mask
Enable
Defines the operation of proximity anti masking detection.
[1] Disable [2] Enable