ProSYS Version 7.XX - Supplementary Instructions
15
Quick Keys Parameter
Default
Range
The following table describes how the three MSs use the primary,
secondary and backup time intervals in the various MS report split
options.
MS report
split for
urgent
events
MS #1
Polling
State
MS #2
Polling
State
MS #3
Polling
State
DO NOT
CALL
N/A N/A
N/A
CALL 1
ST
Primary
N/A
N/A
CALL 2
ND
N/A Primary
N/A
CALL 3
RD
N/A
N/A
Primary
CALL ALL
Primary
Primary
Primary
1
ST
BKUP
2
ND
Primary
If (MS#1 is OK)
Secondary
Else (MS#1
Failed)
Backup
N/A
1
ST
BK
2
ND
3
RD
Primary
If (MS#1 is OK)
Secondary
Else (MS#1
Failed)
Backup
If (MS#2 is OK)
Secondary
Else (MS#2
Failed)
Backup
1
ST
BK 3
CALL2
Primary
Primary
If (MS#1 is OK)
Secondary
Else (MS#1
Failed)
Backup
2
ND
BK 3
CALL1
Primary
Primary
If (MS#2 is OK)
Secondary
Else (MS#2
Failed)
Backup
Important note:
The installer must manually enter the report code value of 87 under the Report
Codes programming menu using quick keys [6][8][0][4]. This value represents
SIA code ZZ and Contact ID code 999 that are used to validate the report
process.
[5][0][4][1] IP Primary
00003 (x10
sec)
0-65535 sec
Defines the polling interval through the primary channel. When using
the default time, a polling message is sent every 30 seconds.
When the IP Primary polling time is defined as 0, no polling message
is sent to the MS (when the MS channel is in the Primary polling
mode).