ProSYS Version 7.XX - Supplementary Instructions
b. Select the zone that the Bus Zone was assigned to and press
/
.
c.
Use the following tables to configure the parameters for the relevant
iWISE Bus detector.
Bus Zone Parameters: iWISE DT Grade 2
Quick Keys Parameter
Default
Range
[2][0][3][zz]
[1]
LEDS
On
Defines the LEDS operation mode.
[2][0][3][zz]
[1] [1] to [2]
LEDS Options
1) Off - Disables the LEDS operation.
2) On – Enables the LEDS operation.
[2][0][3][zz]
[2]
MW (Microwave) Range
Trimmer
Defines the microwave channel range.
[2][0][3][zz]
[2] [1] to [7]
MW Range Options
1) Minimum 2) 25% 3) 50% 4) 65% 5) 85% 6) Maximum 7) Trimmer
(MW is defined by the trimmer setting on the PCB)
[2][0][3][zz]
[3]
ACT
No
Defines the Anti-Cloak™ Technology (ACT) operation mode.
[2][0][3][zz]
[3] [1] to [2]
ACT Options
1) No - Disables the ACT mode.
2) Yes – Enables the ACT mode.
[2][0][3][zz]
[4]
Automatic Microwave Bypass
No
Defines whether the MW channel will be bypassed or not while the
detector identifies trouble in the MW channel.
[2][0][3][zz]
[4] [1] to [2]
Automatic Microwave Bypass Options
1) No - While detecting a problem in the MW channel it is not
bypassed. Alarm condition cannot be established until the MW
channel is fixed.
2) Yes - Switches the detector to operate only in PIR mode in case of
MW trouble.
[2][0][3][zz]
[5]
Green Line
Yes
A feature that follows environmental guidelines by avoiding surplus
emission. This feature defines the activation of the microwave
channel while the system is disarmed.