Page 6, Standard (2 wire) zone wiring, Gt490x control panel – RISCO Group GT490X User Manual
Page 7: Novagard 2g/4g (strobe terminals omitted)

Fig.5 Control Panel Input (Zone) Connections
Fig.4 Typical Novagard 2G/4G Connections
Page 6
+12V
0V
S-
ST-
R TMP
F TMP
BELL+
BELL-
SAB TMP
BELLHOLD-
STROBE-
GT490X Control Panel
N/C Devices
N/C Devices
N/C Devices
N/C Devices
N/C Devices
N/C Devices
N/C Devices
N/C Devices
6k8
6k8
4k7
4k7
4k7
4k7
4k7
4k7
4k7
4k7
Tamper Zone
becomes Zone 9
ONLY when 9 (EOL)
is selected
4k7
N/C Devices
AZ1
+ -
AZ2
+ -
AZ3
+ -
AZ4
+ -
AZ5
+ -
AZ6
+ -
AZ7
+ -
AZ8
+ -
TZ
+ -
N/O Devices (PA etc)
connect across Tamper & Zone
N/C Devices
multiple devices are in series
N/C Devices
N/C Devices
N/C Devices
N/C Devices
N/C Devices
N/C Devices
Standard (2 Wire) Zone Wiring
Novagard 2G/4G
(Strobe terminals omitted)
Please see Page 19 for further
wiring modes where Anti-Mask
detectors are used.
End of Line Zone Wiring
A maximum of four detectors per
zone may be use with EOL wiring
PR5846 Rev12 490X QS Eng.qxd 10/05/2012 11:38 Page 7